2. Measure the resistance between the connecting terminals with an ohmmeter (Figure 15.5a, b).
Nominal value: resistance between power source and ground: 192±19.2 Ohm, between power source and fuel level gauge: 89±8.9 Ohm, between fuel level gauge and ground: 103±10.3 Ohm.
Figure 15.5a. Checking the resistance of the fuel gauge (vehicles with a tachometer) |
Figure 15.5b. Checking the resistance of the fuel gauge (cars without a tachometer) |