- Remove the relay (Fig. 18.9).
Fig. 18.9. Location of the fan relay and relay connector contacts
- Check the conductivity between the relay contacts.

- If the conductivity is different from the required value, replace the relay.
Checking the condenser fan relay
- Remove the turnip (Fig. 18.10).
- Check the conductivity between the relay contacts.
Fig. 18.10. Location of the condenser fan relay and relay connector contacts

The material is based on data from the website [MITSUBISHIMAN.ru]
- If the conductivity is different from the required value, replace the relay.
Front Air Conditioner Test Temperature Characteristics Table
| Ambient temperature,°C | 20 | 25 | 35 | 40 |
| Outlet air temperature,°C | 2,5-4,5 | 2,5-4,5 | 4,5-6,5 | 6,5-9,0 |
| Compressor high pressure, kPa | 765-960 | 765-960 | 1325-1420 | 1570-1765 |
| Low compressor pressure, kPa | 40-135 | 40-135 | 80-175 | 155-255 |