1. Prepare the vehicle for testing (warm up the engine to operating temperature)
2. Disconnect the ventilation hose from the PCV valve and connect a vacuum gauge to the ventilation hose (Fig. 2.10). Start the engine, check the crankshaft speed at idle and the vacuum gauge reading.
Fig. 2.10. Checking the vacuum in the intake manifold using a vacuum gauge
Minimum value on the vacuum gauge: 34 kPa