Pic. 8.4. Intermediate Connector Location (1) nozzles
2. Disconnect the intermediate connector of the injectors (see fig. 8.4).
3. Turn the ignition key to position «ON» («ON»).
4. Select the required item in the menu «Data list» (data table) instrument MUT-II.
5. Crank the engine with the starter for 2 seconds or more and visually check that there is no fuel leakage from the connections.
Attention! If there are fuel leaks, stop the engine immediately and fix the source of the leak.
6. Turn the engine crankshaft with a starter and measure the fuel pressure 20 seconds after the end of crankshaft cranking.
The limiting pressure value is at least 1 MPa.
Attention! If the fuel pressure is less than 1 MPa, it means that there are leaks in the high pressure fuel system.
7. Turn the ignition key to position «OFF» («OFF»).
8. Connect the intermediate connector of the injectors.
9. Disconnect the MUT-II.